The fast boiler

Maintenance personnel should maintain equipment in strict accordance with relevant regulations

Time : 2021-07-27
1. Before putting it into operation, the technicians should study in detail the random manual and various other technical materials, and have an in-depth understanding of the various technical performance of the equipment. And work out the operating procedures for the use of equipment, and the boiler can be put into operation only after necessary technical training for the use or operator of the natural gas boiler.
2. Maintenance personnel should maintain the equipment in strict accordance with relevant regulations to keep the equipment in good condition.
3. If one of the following conditions cannot be protected, an emergency stop should be made
(1) The water level of the natural gas boiler is lower than the visible edge of the lower part of the water level gauge. The water supply is continuously increased and other measures are taken, but the water level continues to drop
(2) The water level of the natural gas boiler exceeds the maximum visible water level (full water), even if the water is discharged, the water level is not visible
 (3) The soft water system is faulty, water cannot be fed into the boiler and the boiler water level is lower than the visible edge of the lower part of the water level gauge;  
 (4) When the circulation pump of the natural gas boiler fails to operate normally;  
 (5) The natural gas boiler components are damaged, endangering the safety of operating personnel;  
(6) The temperature of the boiler water rises sharply out of control;
 (7) Other abnormal conditions endanger the safe operation of natural gas boilers.
4. When the boiler is shut down due to a water shortage accident, it is strictly forbidden to supply water and exhaust the boiler.
5. Ventilation should be good.
6. After the circulation pump is running normally, start the burner and open the circulation system valve. It is forbidden to start the burner first, start the circulating pump or open the valve suddenly after the boiler heats up.
7. The boiler circulating pump stops due to failure, the boiler protection system fails, and the boiler is dry. It is strictly forbidden to add water to the natural gas boiler or open the circulating pump.
8. To stop the furnace, press the stop button on the operation screen to stop the combustion of the burner and close the intake valve. Cut off the power supply of the controller and cut off the main power supply of the boiler.
Hot products
Full premixed condensing steam boiler

Full premixed condensing steam boiler

See more

Capacity: 1-20 t/h

Rated thermal efficiency: 100-104%

Rated working pressure: ≤1.6Mpa

Applicable fuel: Natural gas etc.

WNS integrated condensing steam boiler

WNS integrated condensing steam boiler

See more

Capacity: 1-20 t/h

Rated thermal efficiency: 100-104%

Rated working pressure: ≤3.82Mpa

Applicable fuel: Natural gas, heavy oil, etc

WNS split type condensing steam boiler

WNS split type condensing steam boiler

See more

Capacity: 1-20 t/h

Rated thermal efficiency: 97-100%

Rated working pressure: ≤3.82Mpa

Applicable fuel: Natural gas, diesel oil, etc